One- and three-phase power supplies
Benefits of our power supplies (one- and three-phase power supplies)
- Single-phase and three-phase power supply units as well as customer-specific applications possible
- Adaptation and flexibility to specific customer requirements and broad portfolio
- High quality, long usability and robust power supply made in Germany
- Available as standard or customer-specific solution
Single-phase power supplies
Single-phase power supply unit series FGSE

Type series FGSE according to VDE 0570 / EN 61558 Part 2 – 6
- Ripple < 5 %
- Open installation design
- Rated current range 1 – 6 A
- Protection class IP 00
- Transformer according to VDE 0570 Part 2 – 6, protection class I
- Ambient temperature max. 60° C
- Screw terminals with self-lifting
Disc for conductor cross-section up to 1.5 mm2 - Additional flat connector 2.8 x 0.8 DIN 46244
- Foot angle fastening
- Short-circuit protection due to internal fine securing
5 x 20 in DC circuit - PFC according to EN 61000-3-2
- Contact protection according to VBG 4
- Output rated voltage 24 VDC according to DIN 19240
- Idle voltage < 30.2 VDC at
6 % grid overvoltage - Full load voltage > 20.4 VDC
at 10 mains undervoltage - LED power indicator
- Switch-on time 100
Position
- Wall-mounted, clamps horizontally up and down
- In case of different assembly
approx. 20 performance reduction
Single-phase network device type series ESKE

Type series ESKE according to VDE 0570 / EN 61558 Part 2 – 6 ripple < 5
- Open installation design
- Rated current range 10 – 16 A
- Protection class IP 00
- Transformer according to VDE 0570 Part 2 – 6, protection class I
- Shield winding between primary and secondary
- Ambient temperature max. 60° C
- Connection to contact-protected
Screw terminal - Foot angle fastening
- Protection external
- PFC according to EN 61000-3-2
- Contact protection according to VBG 4
- Output rated voltage 24 VDC according to DIN 19240
- Idle voltage < 30.2 VDC
at 6 mains overvoltage - Full load voltage > 20.4 VDC
at 10 mains undervoltage - Switch-on time 100
Position
- Cooling ribs perenning
- In case of different assembly
approx. 20 performance reduction
Three-phase power supplies
Three-phase power supply
Type series DSK/ DSKE

Type series DSKE with sieve-Elkos residual ripple < 3
Type-reel DSK without sieve-Elkos residual ripple < 5
according to VDE 0570 / EN 61558 Part 2 – 6
- Ripple < 5 or < 3
- Open installation design
- Rated current range 6 – 40 A
- Protection class IP 00
- Transformer according to VDE 0570 Part 2 – 6, protection class I
- Shield winding between primary and secondary
- Ambient temperature max. 60° C
- Connection to contact-protected screw terminals
- Foot angle fastening
- Protection external
- 137-106 and 137-106.200 with internal fine fuse 6.3 A
- PFC according to EN 61000-3-2
- Contact protection according to VBG 4
- Output rated voltage 24 VDC according to DIN 19240
- Idle voltage < 30.2 VDC at
6 Mains overvoltage - Full load voltage > 20.4 VDC at
10% grid undervoltage - Switch-on time 100
Position
- Cooling ribs perenning
- In case of different assembly
approx. 20% performance reduction
Customer-specific applications
Trafonetzteil Large kitchens

Requirements
- Underdistributed output voltages
- Output voltage in DC and AC
- Secured output voltage due to
Car fuse / flat fuse
Trafonetzteil Mechanical Engineering

Application: Mechanical Engineering
- Input 3 x 196 – 500 VAC
- Efficiency 94%
- Secondary voltage 1: 24 VDC / 36 A
- Secondary voltage 2: 1 x 120 VAC / 720 VA
or: 1 x 230 VAC / 920 VA - Safety according to EN 61558-2-4 / UL / CSA T 40 / A
- Shield winding between primary and secondary winding
- Load distribution on board with flat fuses
- Connection to contact-protected spring force
(Wago / Ria Connect) - Installation in the control cabinet floor: lying down
- Ambient temperature max. 40° C
Trafonetzteil Mechanical Engineering

Application: Mechanical Engineering
according to VDE 0570 / EN 61558 Part 2 – 6
- Stabilized
- Open installation design
- Input voltage 230 / 400 V x 10
- Frequency 50 / 60 Hz
- Primary current 0.14 A / Inrush current 1.67 A
- Output voltage 10 VDC / 1.0 A stabilized
- With internal G-fuse 1.0 AT
- Insulation class T 60 / B
- Protection class IP 00
- Protection class I
- Ambient temperature max. 60° C
- Screw terminals with self-lifting disc
for conductor cross-section up to 1.5 mm2 - Foot angle attachment: mounting position wall-hanging,
Clamps horizontally at the top and bottom, in case of
softening assembly approx. 20 performance reduction - LED power indicator in DC circuit
- Contact protection according to VGB 4
We are happy to answer your questions
Click here to get in touch with us