One-phase transformer
Benefits of our single-phase transformers
- Reduction of primary voltage to the required secondary voltage
- Adaptation and flexibility to specific customer requirements and wide portoflio
- High quality, long usability and robust power supply made in Germany
Examples of our single-phase transformers
Type series RTD

Series RTD W40 to W160 according to VDE 0570 / EN 61558 Part 2-6
- Jacket transformer / EJ sheet cut
- Power range 63 – 250 VA, frequency 50 / 60 Hz
- Protection class IP 00, suitability for installation up to IP 20
- Protection class I, insulation class T 40 / B
- Separate windings
- Screw terminals with self-lifting disc
- for conductor cross-section up to 1.5 mm2
- Additional flat connector 2.8 x 0.8 DIN 46244
- Foot angle fastening
- Contact protection according to VBG 4
- Standard screw-on dimensions according to DIN 41308 (e1 x f1)
- Switch-on time 100
Type series UTEN

Type series UTEN G24 to G160 according to VDE 0570 / EN 61558
- Jacket transformer / EJ sheet cut
- Power range 40 – 250 VA
- Frequency 50 / 60 Hz
- Protection class IP 00
- Installation suitability up to IP 20
- Protection class I
- Insulation class T 40 / B
- Separate windings
- Vacuum soaked
- Transformer terminals
- Foot angle fastening
- Contact protection according to VBG 4
Type series UTUB

Type series UTUB / UTUBL (K 1.2 to K 20,0) according to VDE 0570 / EN 61558
- Nuclear transformer / UJ sheet cut
- Power range 1.6 – 20.0 kVA
- Frequency 50 / 60 Hz
- Protection class IP 00
- Installation suitability up to IP 20
- Protection class I
- Insulation class T 40 / B
- Separate windings
- Vacuum soaked
- Terminals
- Foot angle fastening: UTUB standing to the ground
- mounting, UTUBL lying for wall mounting
- Contact protection according to VBG 4
- With air duct, installation position persecuting, approx. 10 reduction in performance when mounted horizontally
Type series UTEB

Type series UTEB (G200 to G1450) according to VDE 0570 / EN 61558
- Jacket transformer / EJ sheet cut
- Power range 320 – 2500 VA
- Frequency 50 / 60 Hz
- Protection class IP 00
- Installation suitability up to IP 20
- Protection class I
- Insulation class T 40 / B
- Separate windings
- Vacuum soaked
- Transformer terminals
- Foot angle fastening
- Contact protection according to VBG 4
- Standard screw-on dimensions according to DIN 4130
Single-phase safety transformers
Type series FEST

Type series FEST (J40 to J160) according to VDE 0570 / EN 61558 Part 2 – 6
- Jacket transformer / EJ sheet cut
- Power range 320 – 2500 VA
- Frequency 50 / 60 Hz
- Insulation class T 40 / B
- Protection class IP 00
- Installation suitability up to IP 20
- Protection class I
- Separate windings
- Transformer terminals
- Vacuum soaked
- Foot angle fastening
- Contact protection according to VBG 4
Type series UTEB

Type series UTEB (G200 to G1450) according to VDE 0570 / EN 61558
- Jacket transformer / EJ sheet cut
- Power range 320 – 2500 VA
- Frequency 50 / 60 Hz
- Protection class IP 00
- Installation suitability up to IP 20
- Protection class I
- Insulation class T 40 / B
- Separate windings
- Vacuum soaked
- Transformer terminals
- Foot angle fastening
- Contact protection according to VBG 4
- Standard screw-on dimensions according to DIN 4130
Single-phase control transformers
Type series FST

Type series FST (L 40 to L160) according to VDE 0570 / EN 61558 Part 2 – 2/4
- Jacket transformer / EJ sheet cut
- Power range 63 – 250 VA, frequency 50 / 60 Hz
- Protection class IP 00, suitability for installation up to IP 20
- Protection class I, insulation class T 40 / B
- Separate windings, primarily 2 taps . . . . . . . . . . . . . . . . . .
- Screw terminals with self-lifting disc for conductor cross-section up to 1.5 mm2
- Additional flat connector 2.8 x 0.8 DIN 46244
- Foot angle fastening
- Contact protection according to VBG 4
- Standard screw-on dimensions according to DIN 41308 (e1 x f1)
- Switch-on time 100
Type series SETB

Type series SETB (U200 to U 1450) according to VDE 0570 / EN 61558 Part 2 – 2 / 4
- Jacket transformer / EJ sheet cut
- Power range 320 – 2500 VA
- Frequency 50 / 60 Hz
- Insulation class T 40 / B
- Protection class IP 00, installation suitability up to IP 20, protection class I
- Separate windings, primarily 2 taps +/-5%
- Vacuum soaked
- Transformer terminals
- Foot angle fastening
- Contact protection according to VBG 4
- Standard screw-on dimensions according to DIN 41308
- Switch-on time 100
Type series SETB/ SETBL

Type series SETB / SETLB (N1,2 to N 20.0) according to VDE 0570 / EN 61558 Part 2 – 2/4
- Nuclear transformer / UJ sheet cut
- Power range 1.6 – 20.0 kVA
- Frequency 50 / 60 Hz
- Insulation class T 40 / B
- Protection class IP 00
- Installation suitability up to IP 20
- Protection class I
- Separate windings, primarily 2 taps . . . . . . . . . . . . . . . . . .
- Vacuum soaked
- Terminals
- Foot angle fastening: SETB standing to the ground
mounting, SETLB lying for wall mounting - Contact protection according to VBG 4
- With air duct, installation position persether, with horizontal
Assembly approx. 10 performance reduction
- VBG 4
- Standard screw-on dimensions according to DIN 41308
- Switch-on time 100
Type series SETLB

Type series SETBL(N 2,4 – N 10,0) according to VDE 0570 / EN 61558 Part 2 – 2/4
- Nuclear transformer / UJ sheet cut
- Power range 3.2 – 12.0 kVA
- Frequency 50 / 60 Hz
- Insulation class T 40 / B
- Protection class IP 00, installation suitability up to IP 20, protection class I
- Separate windings, primarily 2 taps +/-5%
- Vacuum soaked
- Terminals
- Foot angle fastening
- Contact protection according to VBG 4
- With air duct, installation position perceitly, with different installation approx. 10 power reduction
- Switch-on time 100
Type series SETN

Type row SETN (O24- O650) according to
VDE 0570 / EN 61558 Part 2 – 2/4
- Jacket transformer / EJ sheet cut
- Power range 40 – 850 VA
- Frequency 50 / 60 Hz
- Insulation class T 40 / A
- Protection class IP 00
- Installation suitability up to IP 20
- Protection class I
- Separate windings, primarily 2 taps . . . . . . . . . . . . . . . . . .
- Vacuum soaked
- Transformer terminals
- Foot angle fastening
- Contact protection according to VBG 4
Type series FTUL

Type series FTUL 24 to FTUL 1451 according to VDE 0570 / EN 61558 Part 2 – 2 / 4 and UL 506. As a saving winding according to VDE 0570 / EN 60558 Part 2 – 13 with index –
- Jacket transformer / EJ-
- Sheet metal cutting
- Power range 40 – 3000 VA
- Frequency 50 / 60 Hz
- Insulation class T 40 / B
- Protection class IP 00
- Installation suitability up to IP 20
- Protection class I
- Separate windings
- Savings winding recognizable by ending -A (e.g. FTUL 24-A)
- Vacuum soaked
- Transformer terminals
- Foot angle fastening
- Contact protection according to VBG 4
- Switch-on time 100%
Single-phase stage transformers and universal control transformers
Type series USTN/ USTB

Type series USTN /USTB (Q 60 to Q 1450 ) according to VDE 0570 / EN 61558 Part 2 – 2/4
- Jacket transformer / EJ sheet cut
- Power range 80 – 2000 VA
- Frequency 50 / 60 Hz
- Insulation class T 40 / B
- Protection class IP 00, installation suitability up to IP 20, protection class I
- Separate windings, primarily 200 – 550 V switchable
- Vacuum soaked from Q 200
- Line-up clamps
- Foot angle fastening
- Contact protection according to VBG 4
- Standard screw-on dimensions according to DIN 41308
- Switch-on time 100%
Type series UST/LB

Type series USTLB (P 2.4 to P 2.5nach VDE 0570 / EN 61558 Part 2 – 2/4
- Nuclear transformer / UJ sheet cut
- Power range 2.6 – 3.2 kVA
- Frequency 50 / 60 Hz
- Insulation class T 40 / B
- Protection class IP 00, installation suitability up to IP 20, protection class I
- Separate windings
- Vacuum soaked
- Terminals
- Foot angle fastening
- Contact protection according to VBG 4
- With air duct, installation position percecrother, in case of different
of the assembly approx. 10 performance reductions - Switch-on time 100%
Type series USTB / USTLB

Type series USTB / USTLB ( P2.4 to P 20.0 according to VDE 0570 / EN 61558 Part 2 – 2/4
- Nuclear transformer / UJ sheet cut
- Power range 2.6 – 16.0 kVA
- Frequency 50 / 60 Hz
- Insulation class T 40 / B
- Protection class IP 00, installation suitability up to IP 20, protection class I
- Separate windings
- Terminals
- vacuum-soaked
- Foot angle fastening: USTB standing to the ground
mounting, USTLB lying for wall mounting - Contact protection according to VBG 4
- With air duct, installation position persether, with horizontal
Assembly approx. 10% performance reduction
Type series SFTE/STEBL

Type series SFTE /STEBL (W 60 to W 160, S 250 to S 650 according to VDE 0570 / EN 61558 Part 2 – 13
- Jacket transformer / EJ sheet cut
- Power range 1.5 – 18 A, frequency 50 / 60 Hz
- Savings winding
- Protection class IP 00, installation suitability up to IP 20,
Protection class I
- Insulation class T 40 / B
- Foot angle fastening
- Contact protection according to VBG 4
- Switch-on time 100
Type W 60 to W 160
- Screw terminals with self-lifting disc for conductor cross-section up to 1.5 mm2
- Additional flat connector 2.8 x 0.8 DIN 46244
Type S 250 to S 650
- Vacuum soaked
- Angle for wall fixing
- Line-up clamps